Description
Upon request: Outer cover made by oven painted steel sheet
Three-phase electrical back-up with thermostat DN 1 ½” of 6 or 9 kW
TECHNICAL SPECIFICATIONS | BLGLL 750 | BLGLL 1000 | BLGLL 1500 | BLGLL 2000 | BLGLL 3000 | BLGLL 4000 | BLGLL 5000 | BLGLL 7000 | BLGLL 9000 | ||
---|---|---|---|---|---|---|---|---|---|---|---|
d | Internal diameter | mm | 800 | 800 | 1100 | 1200 | 1300 | 1500 | 1600 | 1800 | 2000 |
D | External diameter | mm | 1000 | 1000 | 1300 | 1400 | 1500 | 1700 | 1800 | 2000 | 2200 |
H | Total height | mm | 1800 | 2000 | 2000 | 2000 | 2500 | 2650 | 2750 | 3200 | 3300 |
Weight of the cylinder | kg | 265 | 405 | 420 | 490 | 645 | 850 | 930 | 1400 | 1800 | |
Weight of the 3,2 m² coil | kg | 78 | 78 | 78 | 78 | 78 | – | – | – | – | |
Weight of the 5,4 m² coil | kg | 109 | 109 | 109 | 109 | 109 | 109 | 109 | – | – | |
Weight of the 7,8 m² coil | kg | – | – | – | – | – | – | – | 154 | 154 | |
Weight of the outer cover | kg | 14 | 16 | 20 | 24 | 34 | 39 | 45 | 58 | 67 | |
Cylinder thickness | mm | 4 | 4 | 5 | 5 | 5 | 6 | 6 | 7 | 8 | |
Cover thickness | mm | 4 | 4 | 6 | 6 | 6 | 7 | 7 | 8 | 9 | |
Maximum working temperature | °C | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | |
Maximum working pressure | bar | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
Maximum pressure of the water | bar | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
Maximum working pressure of the coils | bar | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
Insulation ( P.U.) | Soft | Soft | Soft | Soft | Soft | Soft | Soft | Soft | Soft | ||
Insulation’s thickness | mm | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |
Maximum working temperature of the coils | °C | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |
VEN (ventilation) | Inch | 1 1/2″ | – | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | |
Drain | Inch | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | |
A | Hot water outlet HWO | mm/Inch | 1410/1 1/2″ | 1670/1 1/2″ | 1680/2″ | 1680/2″ | 2185/2″ | 2245/3″ | 2245/3″ | 2775/4″ | 2775/4″ |
B | Cold water inlet CWI | mm/Inch | 275/1 1/2″ | 295/1 1/2″ | 295/2″ | 295/2″ | 315/2 1/2″ | 385/3″ | 385/3″ | 415/4″ | 415/4″ |
E | Recirculation R | mm/Inch | 1210/1″ | 1507/1″ | 1495/1 1/2″ | 1495/1 1/2″ | 1986/1 1/2″ | 2050/3″ | 2050/3″ | 2585/3″ | 2585/3″ |
F | Electrical back-up socket ΕΗ2 | mm/Inch | 1187/1 1/2″ | 1198/1 1/2″ | 1180/1 1/2″ | 1180/1 1/2″ | 1490/1 1/2″ | 1725/1 1/2″ | 1725/1 1/2″ | 2280/1 1/2″ | 2280/1 1/2″ |
L | Electrical back-up socket ΕΗ1 | mm/Inch | 500/1 1/2″ | 515/1 1/2″ | 520/1 1/2″ | 520/1 1/2″ | 530/1 1/2″ | 565/1 1/2″ | 565/1 1/2″ | 595/1 1/2″ | 595/1 1/2″ |
A | Thermometer socket T | mm/Inch | 1410/1/2″ | 1670/1/2″ | 1680/1/2″ | 1680/1/2″ | 2185/1/2″ | 2245/1/2″ | 2245/1/2″ | 2775/1/2″ | 2775/1/2″ |
G | Sensor socket ΤR | mm/Inch | 1210/1/2″ | 1507/1/2″ | 1495/1/2″ | 1495/1/2″ | 1985/1/2″ | 2050/1/2″ | 2050/1/2″ | 2585/1/2″ | 2585/1/2″ |
C | Sensor socket S | mm/Inch | 1000/1/2″ | 1155/1/2″ | 1150/1/2″ | 1150/1/2″ | 1485/1/2″ | 1505/1/2″ | 1505/1/2″ | 1835/1/2″ | 1835/1/2″ |
I | Sensor socket S | mm/Inch | 510/1/2″ | 525/1/2″ | 530/1/2″ | 530/1/2″ | 510/1/2″ | 585/1/2″ | 585/1/2″ | 615/1/2″ | 615/1/2″ |
K | Recirculation R | mm/Inch | 560/1″ | – | 845/1 1/2″ | 845/1 1/2″ | 1015/1 1/2″ | 1035/3″ | 2050/3″ | 1065/3″ | 1065/3″ |
L | Extractible coil C1 | mm | 500 | 515 | 520 | 520 | 530/td> | 565 | 565 | 595 | 595″ |
F | Extractible coil C2 | mm | 1187 | 1198 | 1180 | 1180 | 1490/td> | 1725 | 1725 | 2280 | 2280 |
A | Extractible coils’ diameter | mm | 508 | 508 | 508 | 508 | 508/td> | 508 | 508 | 508 | 508 |